3 function, Industrial pc | parameter setting & configuration, Ipc backup & restore function – Lenze PC-based Automation Industrial PC User Manual

Page 66

Advertising
background image

Industrial PC | Parameter setting & configuration

IPC backup & restore

Function

66

L

2.5 EN - 01/2012

9.3

Function

The software and the operating system of the Industrial PC are stored on the CF card. With

»IPC Backup & Restore« for Windows® CE you have the possibility of saving data from the

CF card to a USB stick.
A backup created like this can be transferred from the USB stick to the CF card anytime by

restoring the data.
Furthermore a software update from a USB stick can be installed on the CF card of the

Industrial PC by means of »IPC Backup & Restore«.
The entire update process comprises several individual steps and is processed as follows.

Backup of the current system before changes have been carried out, in the following

referred to as Backup_orig.

Migration of the existing databases to the new structure, in the case of a version

change.

Installation of the SW update containing the Lenze software and the operating system.

The update process contains several successive steps; the sequence step is only carried out

if the previous step was carried out successfully. In order to be able to trace this sequencer,

log messages are written throughout the procedure.
The log messages signal the steps that have been carried out.

Update Process

Update required?

M1

Identical version

Yes

Backup of original

Backup OK?

No

M2

MIGRATION

MIGRATION

Status

Running/
Rollback failed

RESTORE

UPDATE

OK

Failed/rollback OK

M5

Update OK?

Restore OK?

REBOOT

No

No

Yes

Yes

M3

M7

M4

M8

Advertising