Schwank STW-JZ1 User Manual

Page 45

Advertising
background image

45

STW-JZ / IW I&O Manual

IM101229

RL: 12A- BA

RD: DEC 2010

FIGURE 22 HANGER SPACING / AIR INTAKE TO VENT LENGTH

FIGURE 8 HANGER / REFLECTOR ORIENTATION HORIZONTAL TO 45

0



POSITION BURNER END HANGER 6.5 INCHES (17 CM) FROM BURNER [2.5 INCHES (6.4 CM)
FROM TUBE FLANGE]



POSITION SYSTEM HANGERS 116 INCHES (295 CM) APART

* ANGLE BURNER SUPPORT CHAIN BACK OVER BURNER - ALLOWS TUBE SYSTEM EXPANSION

Tube
Length

L’ = center air intake to end

10’

11’-3 3/4” ; 135 3/4” ; 345 cm

20’

20’-11 3/4” ; 251 3/4” ; 628 cm

30’

30’-7 3/4”

; 367 3/4” ; 934 cm

40’

40’-3 3/4”

; 483 3/4” ; 1229 cm

Tube
Length

L’ = center air intake to end

50’

49’-11 3/4” ; 599 3/4”

; 1523 cm

60’

59’-7 3/4”

; 715 3/4”

; 1818 cm

70’

69’-3 3/4”

; 831 3/4”

; 2113 cm

*

Advertising