Regency Horizon™ HZ40E-2 Gas Fireplace

INSTALLATION

WALL MOUNT ON / OFF SWITCH AND BATTERY COMPARTMENT INSTALLATION

AND/OR RECEIVER INSTALLATION

REQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLS

J-Box

Receiver

Wall Plate

Slider Switch

Low Voltage Junction Box

Diagram 1

10 ft. wire harness with

12 pin connector

I

MPORTANT INSTALLATION NOTE:

The Receiver must be placed inside the supplied (Low Voltage)

junction type wall box and installed into the wall only.

DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE.

Remote Receiver Installation

1. Install the low voltage junction box to the framing, at desired location within 10 ft. from fi replace.

2. Feed the 12 pin connector through the opening at back of junction box.

3. Connect the 12 pin connector to the back of the receiver.

4. Install the Receiver in the Low Voltage Junction box.

5. Insert the 4 AA type batteries in the battery compartment with the correct polarity.

6. Place the slider into the cover plate.

7. Put the Receiver switch in the “OFF” position, to allow correct lineup for slider switch.

8. Make sure the Receiver and cover plate words “ON” and “UP” are on the same side.

9. Align the slider with the switch on the Receiver and couple the switch into the slider.

10. Align the screw holes.

11. Using the two (2) screws provided secure the cover plate to the Receiver.

Optional Profl ame Receiver