26

Regency Horizon™ HZ40E-2 Gas Fireplace

INSTALLATION

Horizontal Venting with Two (2) 90

o

Elbows

Horizontal Venting with Three (3) 90

o

Elbows

H

H1

V

H1

V

H2

H

One 90

o

elbow = Two 45

o

elbows.

Option

V

H + H1

With these options, maximum
total pipe length is 28 feet
with minimum of 6 feet total
vertical and maximum 8 feet
total horizontal.

Please note minimum 1
foot between 90

o

elbows is

required.

A)

1' Min.

3' Max.

B)

2' Min.

4' Max.

C)

3' Min.

5' Max.

D)

4' Min.

6' Max.

E)

5' Min.

7' Max.

F)

6' Min.

8' Max.

One 90

o

elbow = Two 45

o

elbows.

Option

H

V

H + H1 + H2

With these options,
maximum total pipe
length is 28 feet with
minimum of 11 feet
total vertical and
maximum 9 feet total
horizontal.

P l e a s e n o t e
minimum 1 foot
between 90

o

elbows

is required.

A)

1' Max.

1' Min.

3' Max.

B)

2' Max.

3' Min.

5' Max.

C)

3' Max.

5' Min.

6' Max.

D)

4' Max.

7' Min.

7' Max.

E)

5' Max.

9' Min.

8' Max.

F)

6' Max.

11' Min.

9' Max.

H1

H

V

Horizontal Venting with Two (2) 90

o

Elbows

One 90

o

elbow = Two 45

o

elbows.

Option

H

V

H + H1

With these options,
maximum total pipe
length is 28 feet with
minimum of 8 feet total
vertical and maximum
8 feet total horizontal.

Please note minimum
1 foot between 90

o

elbows is required.

A)

1' Max.

1' Min.

3' Max.

B)

2' Max.

2' Min.

5' Max.

C)

3' Max.

4' Min.

6' Max.

D)

4' Max.

6' Min.

7' Max.

E)

5' Max.

8' Min.

8' Max.

Restrictor Position - Set 0 (factory setting)

Restrictor Position - Set 0 (factory setting)

Restrictor Position - Set 0 (factory setting)