Installation, Venting arrangement for vertical terminations, Vertical venting with one(1) 90 – Regency Horizon HZ40E Medium Gas Fireplace User Manual

Page 29: Elbows (1 - 90

Advertising
background image

Regency Horizon™ HZ40E-2 Gas Fireplace

29

INSTALLATION

VENTING ARRANGEMENT FOR VERTICAL TERMINATIONS

Vertical Venting with One(1) 90

o

Elbows (1 - 90

o =

2 - 45

o

)

The shaded area in the diagram shows all allowable combinations
of straight vertical and offset to vertical terminations, using one
90

o

elbow, with Rigid Pipe Venting Systems.

Two 45

o

elbows equal to one 90

o

elbow, not including the

starting 45

o

elbow at the fl ue collar.

• Vent must be supported at offsets.

• Minimum distance between elbows is 1 ft. (305mm).

• Maintain clearances to combustibles as listed in the

"Clearances" section.

• Horizontal vent must be supported every 3 feet.

• Firestops are required at each fl oor level and whenever

passing through a wall.

• Must use optional rigid pipe adaptor (Part# 510-994)

when using rigid pipe vent systems.

• Refer to the "Vent Restrictor Position" section for

details on how to change the vent restrictor from the
factory setting of Set 0 to Set 1 or Set 2 if required.

Maximum: 40 ft. (12.2m)

Minimum

8’6”

(2.6m)

Min. 36-1/4

(921mm)

Max. 10’ (3m)(centerline to centerline)

Minimum length of pipe

between elbows 12” (305mm)

Maximum: 27 ft. (8.2m)

0

2

4

6

40

8

10

12

14

16

18

20

22

24

26

28

30

V

ertical Height (Feet)

32

34

36

38

6

8

Horizontal (Feet)

2

0

4

10

12

16

18

18

14

20

Vent Restrictor on Set 2

Vent Restrictor on Set 3

Vent Restrictor on Set 1