Regency Horizon™ HZ40E-2 Gas Fireplace

INSTALLATION

HORIZONTAL TERMINATIONS

RIGID PIPE 4" X 6-5/8

"

The minimum components required for a basic horizontal
termination are:

1 Horizontal

Termination

Cap

1 45

o

Elbow

1 Rigid Pipe Adaptor (510-994)
1 Wall

Thimble

1 Length of pipe to suit wall thickness
(see

chart)

Wall thickness is measured from the back standoffs to the inside
mounting surface of termination cap. For siding other than vinyl
furring strips may be used, instead of the vinyl siding standoff, to
create a level surface to mount the vent terminal. The Terminal
must not be recessed into siding. Measure the wall thickness
including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl
siding), measure to outside surface of wall without siding and
add 2 inches.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be

used to secure rigid pipe to adaptor.

This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent, Selkirk Direct-Temp,
Ameri Vent Direct Venting, ICC Excel Direct
and Security Secure Vent systems. Use of
these systems with the Rigid Pipe adaptor is
deemed acceptable and does not affect the
Intertek WHI listing of components.

WARNING:

Do not combine venting components from
different venting systems.

However use of the the AstroCap

TM

and FPI

Riser is acceptable with all systems.

The FPI AstroCap

TM

and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent

®

Direct Vent,

American Metal Products Ameri Vent Direct Vent, Security Secure Vent

®

, ICC Excel, Selkirk Direct-Temp. AstroCap

TM

is a proprietary trademark of FPI

Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

Flat Wall Installation

Wall Thickness

(inches)

Vent Length Required

(inches)

4" - 5-1/2"

6"

7" - 8-1/2"

9"

10" - 11-1/2"

12"

9" - 14-1/2'

11" - 14-5/8" Adj. Pipe

15" - 23-1/2"

17" - 24" Adj. Pipe

Adj.Pipe Length

Horizontal

Termination Cap

Wall Thimble

Vinyl Siding

Standoff (Optional)

Rigid Pipe Adapter

45 Elbow

o

Vent Guard

(Part #946-506/