Regency Horizon™ HZ40E-2 Gas Fireplace

5

SAFETY LABEL

This is a copy of the label that accompanies
each HZ40E-NG2 and HZ40E-LP2 Direct Vent
Gas Fireplace. We have printed a copy of the
contents here for your review.

NOTE: Regency

®

units are constantly being

improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.

COPY OF SAFETY DECAL

For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.

For the State of Massachusetts, fl exible con-
nectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.

The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

412

DOOR SEAL: Please

check that the door is

properly sealed

FPI Fireplace Products International Ltd. Delta, BC, Canada

Minimum Clearances to Combustibles /

Degagement Minimum De Materiaux Combustibles

Serial No./ No de serie

919-270

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.

Listed:
Certified for/Certifi e pour:
Tested to:

VENTED GAS FIREPLACE HEATER /

CANADA and U.S.A.

FOYER AU GAZ À ÉVACUATION

é

CAN/CGA-2.17-M91(R2009)

ANSI Z21.88-2009/CSA 2.33-2009

Fan (Part # 256-917)
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. /

NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.

Made in Canada/ Fabrique au Canada

(See Instruction Manual for

detailed instructions)

Й

Й

й

QUIP A L'UISINE POUR GAZ PROPANE

CONCU POUR ETRE POELE: Mod le HZ40E-LP2

PROPANE GAS: Model HZ40E-LP2

Minimum supply pressure
Manifold pressure
Orifice size
Maximum input

Altitude

Minimum input

NATURAL GAS: Model HZ40E-NG2

APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le HZ40E-NG2
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Grandeur de l'injecteur
D bit

maximum selon

l'altitude

Calorifique

й

й

й

й

й

5.0"

(1.25kPa)

3.5"

(0.87kPa)

#40

DMS

0-4500

ft/pi

(0-1372 m)

WC/C.E.
WC/C.E.

26,000 Btu/h

(7.61 kW)

18,000 Btu/h

(5.28 kW)

Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Grandeur de l'injecteur
D bit

maximum selon

l'altitude

Calorifique

й

й

й

й

11“ WC

(2.73 kpa)

WC/C.E.

25,500 Btu/h

(7.47kW)

10"

(2..49kPa)

# 53

DMS

0-4500

ft/pi

(0-1372 m)

21,000 Btu/h

(6.15 kW)

Minimum supply pressure
Manifold pressure
Orifice size
Maximum input

Altitude

Minimum input

D

E

F

A

B

C

Side Walls
A

8” (203mm)

B 22” (559mm)

C

17" (432mm)

D

13” (330mm)

E

84" (1524mm)

F

36" (2134mm)

Ceiling

Min. Mantel Height

Max. Mantel Depth

Alcove Width

Alcove Depth

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in
the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles.

This vented gas fireplace heater is not for use with air filters.

Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.

FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY

Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si
les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si une trousse certifié est utilisé.

POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL