Chapter 5
Programming Parameters

5-12

Table 5.A Cont.

PARM

670

672

673

674

675

676

677

678

679

680

681

682

683

684

685

686

687

688

689

690

691

692

693

698

699

700

701

702

703

704

705

706

707

708

709

710

711

713

714

715

716

UNITS

%

Sec

%

%

%

%

%

%

%

%

%

RPM

RPM

%

RPM

RPM

RPM

Rad/Sec

Rad/Sec

Sec

RPM

RPM

RPM

RPM

RPM

RPM

RPM

SEC

NAME

Slave Percent 2

KI Flux

KP Flux

Fld Economy Ref

Fld Economy Ref

Fld Flux Ref

Fld I @ 0/8 Flux

Fld I @ 1/8 Flux

Fld I @ 2/8 Flux

Fld I @ 3/8 Flux

Fld I @ 4/8 Flux

Fld I @ 5/8 Flux

Fld I @ 6/8 Flux

Fld I @ 7/8 Flux

Fld I @ 1.0Flux

Fld Weaken Spd.

CEMF Reg. Preload

Tach Switch Tol.

Tach Switch Ki

Tach Switch Kp

Tach Switch Select

Kn Filter

Wn Filter

Auto Tune I Lim

Auto Tune Speed

Vel Desired BW

Vel Max BW

Vel Damp Factor

System Inertia

At Speed 1

At Speed 2

At Speed 3

At Speed 4

At Speed 5

Up To Speed Tol

Zero Speed Tol

Jog Dwell

Proc Trim Fltr K

Proc Trim Preload

Proc Trim KI

Proc Trim KP

MIN

–200

0

0

0

0

0.0244

0

0

0

0

0

0

0

0

0

B.S./8

–799.9

0

0

0

0

–32767

1

.0244

– B.S.

0.1

50

1.0

2.0

0

BS/8

BS/4

BS/2

BS

–6xB.S.

0

0

0

–32767

0

0

MAX

200

32767

32767

100

6553.5

125

100

100

100

100

100

100

100

100

100

+6xB.S.

799.9

B.S

65535

65535

1

+32767

500

100

B.S.

150

150

3.0

655.0

+6xB.S.

+6xB.S.

+6xB.S.

+6xB.S.

+6xB.S.

B.S./10

+6xB.S.

6553.5

100

32767

32767

32767

FUNCTION/CLASSIFICATION/PORT

Torque Control/Setup

Field Weak Control/Set-Up

Field Weak Control/Set-Up

Field Flux Control/Set-Up

Field Flux Control/Set-Up

Field Flux Control/Set-Up

Field Flux Control/Autotune

Field Flux Control/Autotune

Field Flux Control/Autotune

Field Flux Control/Autotune

Field Flux Control/Autotune

Field Flux Control/Autotune

Field Flux Control/Autotune

Field Flux Control/Autotune

Field Flux Control/Autotune

Field Weak Control

Field Flux Control

Tach Loss Recovery/Set-Up

Tach Loss Recovery/Set-Up

Tach Loss Recovery/Set-Up

Tach Loss Recovery/Set-Up

Set-Up

Set-Up

Auto Tuning Setup/Autotune

Auto Tuning Setup/Autotune

Auto Tuning Setup/Autotune

Auto Tuning Setup/Autotune

Auto Tuning Setup/Autotune

Auto Tuning Setup/Autotune

Velocity Ref Cntrl/ Spd Ref

Velocity Ref Cntrl/ Spd Ref

Velocity Ref Cntrl/ Spd Ref

Velocity Ref Cntrl/ Spd Ref

Velocity Ref Cntrl/ Spd Ref

Logic Control/Set-Up

Logic Control/Set-Up

Logic Control/Set-Up

Process Trim Control/Set-Up

Process Trim Control/Set-Up

Process Trim Control/Set-Up

Process Trim Control/Set-Up

HEX

2A6H

2A8H

2A9H

2AAH

2ABH

2ACH

2ADH

2AEH

2AFH

2B0H

2B1H

2B2H

2B3H

2B4H

2B5H

2B6H

2B7H

2B8H

2B9H

2C0H

2C1H

2BCH

2BDH

2C2H

2C3H

2C4H

2C5H

2C6H

2C7H

2C8H

2CAH

2CBH

2CCH

2CDH

2CEH

2CFH

2D0H

2D1H

2D2H

2D3H

2D4H

INIT

0

1638

4096

50

30

100

0

6.6

14.3

23.1

33.3

45.5

60.0

77.7

100

B.S.

0

10%B.S

50

10

0

512

300

25

B.S.

5

50

1.0

2.0

0

BS/8

BS/4

BS/2

BS

BS/100

BS/100

0

0

0

1638

4096

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE