Chapter 3
Functional Description

3-27

0

RAMP

BYPASS

3

Pre–Ramp

Vel Ref

102

5

RPM

1,2,5,9,10

LOGIC CMD

150, 151, 152

RAMP CONTROL

RPM

RPM

FWD SPEED

LIMIT

608

607

REV SPEED

LIMIT

G

STOP LOGIC

PROCESS TRIM

SELECT 628

DESIRED

CONTOUR

653

VELOCITY INDIRECTS

PARAMETER 100 LOGIC
STATUS BIT DEFINITION

AUTO
TUNE

AUTO TUNE SPEED 699

VEL DESIRED BW 700

VEL MAX BW 629

SYSTEM INERTIA 703

CUR DESIRED BW 741

MCUR MAX BW 742

CUR DAMP FACTOR 743

ARM BRIDGE TYPE 733

AUTOTUNE I LIM 698

VEL DAMP FACTOR 702

STOP

COMMAND

11

LOGIC CMD

150, 151, 152

9

10

626

Jog Ramp

Enable

LINEAR

ACCEL/DECEL

RAMP

SEC
SEC

ACCEL TIME 651
DECEL TIME 652

S CONTOUR

FILTER

%

Ramp

Vel Ref

103

RPM

= 3

To Sheet 2

4096 =

Motor

Base Speed

FINAL

VEL REF 104

From Sheet 2

15

AUTO TUNE

AUTO
TUNE
CURRENT

H

AUTO
TUNE
GAINS

VEL. IND. 1

163

VEL. PARAM. 1 SEL

VEL. IND. 2

164

VEL. PARAM. 2 SEL

600

601

VEL. IND. 3

165

VEL. PARAM. 3 SEL

602

VEL. IND. 4

166

VEL. PARAM. 4 SEL

603

NOTE: PARAM. 600 – 603 can specify where to direct data in the range of Param 600–732.
Param 600 – 603 cannot be programmed when the drive is running

SYSTEM INDIRECTS

SP. OUTPUT. 1

10

NOTE: PARAM. 840–844 can specify any constant in the range of + 32,767

840

SP. IND. 1

SP. OUTPUT. 2

11

SP. IND. 2

841

842

843

SP. OUTPUT. 3

12

SP. IND. 3

SP. OUTPUT. 4

13

SP. IND. 4

844

SP. OUTPUT. 5

14

SP. IND. 5

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

FAULTFIELD 0

FAULTFIELD 1

ACTIVE LOGIC COMMAND 0

ACTIVE LOGIC COMMAND 1

CONTACTOR CLOSE

DRIVE RUNNING

RUNNING REVERSE

READY

AT CURRENT LIMIT

AT SET SPEED

AT ZERO SPEED

AT SPEED 1

AT SPEED 2

AT SPEED 3

AT SPEED 4

AT SPEED 5

PARAMETER 150,151,152 LOGIC
COMMAND BIT DEFINITION

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

RUN REFERENCE A

RUN REFERENCE B

RUN REFERENCE C

MOP INCREMENT

MOP DECREMENT

RAMP DISABLE

MOP RATE 1

MOP RATE 2

COMMAND ENABLE

JOG 2

JOG 1

NORMAL STOP

START

CLOSE CONTACTOR

CLEAR FAULT

PROCESS TRIM

PARAMETER 620 SYSTEM RESET SELECT
0 = System Reset with TB3–3
1 = Normal Stop with TB3–3

PARAMETER 624 MAINTAINED START
(150, 151, 152 Bit 12)
0 = MOMENTARY
1 = MAINTAINED
2 = SOFTWARE COAST/ REGEN,STOP OPTION
3 = ALL COAST STOP OPTION

2

1

152

Bit 8 of 152

151

150

Bit 8 of 150

LOGIC COMMAND CONTROL

TO

DRIVE
LOGIC

CONTROL