PARM

717

718

719

720

721

722

724

725

726

727

728

729

730

731

732

733

734

735

736

737

738

739

740

741

742

743

780

840

841

842

843

844

900

901

902

903

904

905

UNITS

%

RPM

RPM

RPM

SEC

SEC

SEC

SEC

%

SEC

%

%

Rad/Sec

Rad/Sec

X.XX

NAME

Proc Tri Lo Lim

Proc Trim Hi Lim

Proce Trim Out K

Ovld Pend Level

Proc Trim Lo Sum

Proc Trim Hi Sum

ABS Overspeed

Ext Overtemp Dly

SCR Overtemp Dly

Stall Delay

AC Line Tol Dly

Field Fault Threshold

Fld Failure Dly

Tach Loss CEMF

Tach Loss Vel

Arm Bridge Type

K Discontinuous

KP Armature Loop

KI Armature Loop

KP Field Loop

KI Field Loop

K Arm Volts

K AC Volts

Cur Desired BW

Cur Max BW

Cur Damp Factor

Firmware Ver No.

SP Indirect 1

SP Indirect 2

SP Indirect 3

SP Indirect 4

SP Indirect 5

Trend Sign Val

Trend Sign Val

Trend Sign Val

Trend Sign Val

Trend Logic Val

Trend Logic Val

MIN

–32767

–32767

–16.0

0.0244

–6xB.S.

+6xB.S.

0

0.1

0.1

0

0

0

0.1

0

.2441

0

33

0

0

0

0

3000

2000

100

100

0.8

–32767

–32767

–32767

–32767

–32767

–32767

–32767

–32767

–32767

0

0

MAX

32767

32767

+16.0

260

0

+6xB.S.

B.S.

3276.7

3276.7

100

1.0

100

5.0

50.0

50.0

1

2048

32767

32767

32767

32767

25000

15000

1000

1000

3.0

32767

32767

32767

32767

32767

32767

32767

32767

32767

*

*

FUNCTION/CLASSIFICATION/PORT

Process Trim Control/Set-Up

Process Trim Control/Set-Up

Process Trim Control/Set-Up

Fault Detection/Set-Up

Process Trim Control/Setup

Process Trim Control/Set-Up

Process Trim Control/Set-Up

Fault Detection/Set-Up

Fault Detection/Set-Up

Fault Detection/Set-Up

Fault Detection/Set-Up

Fault Detection/Set-Up

Fault Detection/Set-Up

Fault Detection/Set-Up

Fault Detection/Set-Up

Auto Tuning Setup/Basic

Current PI Control/Autotune

Current PI Control/Autotune

Current PI Control/Autotune

Field PI Control/Set-Up

Field PI Control/Set-Up

Feedback Control/Basic

Feedback Control/Basic

AutoTuning Setup/Autotune

AutoTuning Setup/Autotune

AutoTuning Setup/Autotune

SP Control/Configuration

SP Control/Configuration

SP Control/Configuration

SP Control/Configuration

SP Control/Configuration

Trend Function

Trend Function

Trend Function

Trend Function

Trend Function

Trend Function

HEX

2D4H

2D5H

2D6H

2D7H

2D8H

2D8H

2D9H

2DCH

2DDH

2DEH

2DFH

2E0H

2E1H

2E2H

2E3H

2E4H

2E5H

2E6H

2E7H

2E8H

2E9H

2EAH

2EBH

2ECH

2EDH

2EEH

348H

349H

34AH

34BH

34CH

INIT

–4096

4096

1.000

115

–6xB.S.

+6xB.S.

B.S./10

1.0

1.0

10.0

0.1

30

1.0

10.01

2.002

1

1024

710

90

16384

168

12500

7225

500

500

1.0

X.XX

0

0

0

0

0

0

0

0

0

0

0

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

* See Parameter Description

Advertising