Rockwell Automation 1747-PCINT API Software for 1746 I/O User Manual

Page 42

Advertising
background image

3–16

Developing Applications

Publication 1747-6.5.3 June 1998

/* Read auto-config */
if (SUCCESS != (rc = OC_GetIOConfiguration(OChandle, &OCcfg)))
{
printf("\nERROR: OC_GetIOConfiguration failed: %d\n", rc);
Ioexit(1);
}

/* Display rack configuration */
slots = OCcfg.Rack1Size + OCcfg.Rack2Size + OCcfg.Rack3Size;
if ( slots > 31 ) slots = 31;

printf("\n\nRack configuration:");
for (i=1; i<slots; i++)
{
if (OCcfg.SlotCfg[i].type != 0xff)
{
printf("\nSlot %2d: Type %2d, Mix %3d %s",
i, OCcfg.SlotCfg[i].type, OCcfg.SlotCfg[i].mix,
OCcfg.SlotCfg[i].Name);
}
else
{
printf("\nSlot %2d: %s", i, OCcfg.SlotCfg[i].Name);
}

/* check for BAS modules class 1 or 4 */
if ( ((OCcfg.SlotCfg[i].mix == 35) || (OCcfg.SlotCfg[i].mix == 131))
&& (OCcfg.SlotCfg[i].type == 6))
{
if ( OCcfg.SlotCfg[i].mix == 35 )
{ /* if Class 1 BAS module, then ...
OCcfg.SlotCfg[i].mix = 131; /* ...make it class 4 */
OCcfg.SlotCfg[i].Name = NULL; /* remove name so that OC_CreateIOConfiguration
will key off mix/type */
fRecreateIOcfg = 1;
}
BASslot = i;
}

/* check for IB32 modules */
if ( OCcfg.SlotCfg[i].mix == 7 )
{
IB32slot = i;
}
}

/* if we converted a Class 1 BAS module to Class 4, recreate the IO configuration */
/* to insure we get the M0 and M1 file sizes */
if (fRecreateIOcfg == 1)
{
if (SUCCESS != (rc = OC_CreateIOConfiguration(&OCcfg)))
{
printf("\nERROR: OC_CreateIOConfiguration failed: %d\n", rc);
Ioexit(1);
}
}

/* Download the configuration to the scanner */
if (SUCCESS != (rc = OC_DownloadIOConfiguration(OChandle, &OCcfg)))
{
printf("\nERROR: OC_DownloadIOConfiguration failed: %d\n", rc);
Ioexit(1);
}

Configure
the scanner
See page
6-11.

Advertising