6–14

Library of Routines

OC_EnableEOSNotify

Publication 1747-6.5.3 June 1998

Return Value:

Considerations:

Supported in the DOS API library and the Windows NT API library

Example:

HANDLE Handle;
int

retcode;

retcode = OC_EnableEOSNotify( Handle, EOSMSG_ENABLE );
/* Use OC_PollScanner() to check EOS messages */

Name:

Value:

Description:

SUCCESS

0

notification was generated successfully

ERR_OCACCESS

2

handle

does not have access to scanner

ERR_OCINIT

5

scanner has not been initialized, see OC_InitScanner

ERR_OCPARAM

8

parameter contains invalid value