Rockwell Automation 1738 Assembly Connections for POINT I/O and ArmorPOINT I/O EtherNet/IP Adapters User Manual

Page 42

Advertising
background image

Publication 1734-UM016A-EN-P - October 2010

36 1734/1738 I/O Module Assembly Information

• 1734-IB8 or 1738-IB8
• 1734-IV8 or 1738-IV8

Configuration Assembly Instance 103

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Input 0 Off to On Filter Low Byte

1

Input 0 Off to On Filter High Byte

2

Input 0 On to Off Filter Low Byte

3

Input 0 On to Off Filter High Byte

4

Input 1 Off to On Filter Low Byte

5

Input 1 Off to On Filter High Byte

6

Input 1 On to Off Filter Low Byte

7

Input 1 On to Off Filter High Byte

8

Input 2 Off to On Filter Low Byte

9

Input 2 Off to On Filter High Byte

10

Input 2 On to Off Filter Low Byte

11

Input 2 On to Off Filter High Byte

12

Input 3 Off to On Filter Low Byte

13

Input 3 Off to On Filter High Byte

14

Input 3 On to Off Filter Low Byte

15

Input 3 On to Off Filter High Byte

16

Input 4 Off to On Filter Low Byte

17

Input 4 Off to On Filter High Byte

18

Input 4 On to Off Filter Low Byte

19

Input 4 On to Off Filter High Byte

20

Input 5 Off to On Filter Low Byte

21

Input 5 Off to On Filter High Byte

22

Input 5 On to Off Filter Low Byte

23

Input 5 On to Off Filter High Byte

24

Input 6 Off to On Filter Low Byte

25

Input 6 Off to On Filter High Byte

26

Input 6 On to Off Filter Low Byte

27

Input 6 On to Off Filter High Byte

28

Input 7 Off to On Filter Low Byte

29

Input 7 Off to On Filter High Byte

30

Input 7 On to Off Filter Low Byte

31

Input 7 On to Off Filter High Byte

Advertising