Configure Using
RSLogix 5000 Software

Refer to the online documentation provided with your programming software or
see Configure the Module for Your EtherNet/IP Network on

page 23

and

Configure the Module Using RSLogix 5000 software on

page 33

.

Configure Using Web
Server

The 1732E EtherNet/IP ArmorBlock Supporting Sequence of Events module
includes an embedded web server which allows viewing of module information,
TCP/IP configuration, and diagnostic information.

For more information on ArmorBlock module embedded web server capability,
refer to Appendix E on

page 123

.

Subnet Mask

The ArmorBlock module subnet mask (in network byte order). The Subnet Mask is used to
interpret IP addresses when the internet is divided into subnets. A Subnet Mask of all zeros
indicates that no subnet mask has been configured.
In this case, the controller assumes a Subnet Mask of 255.255.255.0.

0 (undefined)

read/write

Gateway Address

The address of a gateway (in network byte order) that provides connection to another IP
network. A Gateway Address of all zeros indicates that no gateway has been configured.

0 (undefined)

read/write

Host name

The Host Name is a unique name that identifies a device on a network. It must start with a
letter, end with a letter or digit, and have as interior characters only letters, digits or hyphens.
Maximum length is 64 characters. It must have an even number of characters.

NULL
(undefined)

read/write

Default Domain
Name

The default domain name can have the following formats:
’a.b.c’, ’a.b’ or ’a’, where a, b, c must start with a letter, end with a letter or digit, and have as
interior characters only letters, digits or hyphens. Maximum length is 48 characters.

NULL
(undefined)

read/write

Primary Name
Server

This is the IP address of the computer acting as the local Ethernet network Primary Domain
Name System (DNS) server.

0 (undefined)

read/write

Secondary Name
Server

This is the IP address of the computer acting as the local Ethernet network Secondary Domain
Name System (DNS) server.

0 (undefined)

read/write

DHCP Enable

When DHCP is enabled, a DHCP server automatically assigns network related parameters to
the ArmorBlock module when it logs on to a TCP/IP network. There must be a DHCP server on
the network capable of allocating network addresses and configuring parameters to newly
attached device. When DHCP is disabled, the ArmorBlock module uses the locally configured
network related parameters (IP Address, Subnet Mask, Gateway Address, and so on).

1 (enabled)

read/write

Auto Negotiate and
Port Setting

When Auto Negotiate is disabled (unchecked), the Ethernet speed/duplex is forced to either 10
Mbps/Half-duplex, 10 Mbps/Full-duplex, 100 Mbps/Half-duplex, or 100 Mbps/Full-duplex, as
selected in the Port Setting field.
When Auto Negotiate is enabled (checked), the ArmorBlock module will automatically
negotiate the link speed and duplex with the module it is connected to.

Auto Negotiate
enabled

read/write

Configuration Parameters