Use the default configuration, Change the default configuration – Rockwell Automation 1732E-OB8M8SR EtherNet/IP Dual Port 8-Point SOE Input and Scheduled Output Modules UM User Manual

Page 51

Advertising
background image

Rockwell Automation Publication 1732E-UM003B-EN-E - March 2014

41

Configure the Module Using RSLogix 5000 Software Chapter 6

Use the Default
Configuration

If you use the default configuration and click OK, you are done.
You can skip to Download Your Configuration on

page 43

for instructions on

how to download your default configuration to the controller.

Change the Default
Configuration

If you click Change... in

step D

on

page 40

, you can change the Module

Definition information. Note that the 1732E-IB8M8SOER and 1732E-
OB8M8SR modules have slightly different Module Definition dialogs (1732-
OB8M8SR module does not have the Connection field. The screenshots below
will guide you through the dialog.

Select tabs on the Module Properties dialog to edit specific configuration for your
module in RSLogix 5000 software, for example the Configuration tab.

Some of the screens that appear during this initial module configuration process
are blank (such as Module Info, Network, and Time Sync) and are not shown
here. These screens mostly provide information and status and can be important
during online monitoring. To see these screens in use, see Chapter 10,
Troubleshoot the Module on

page 87

.

When you click Change..., the Module Definition dialog is shown.
Through the Module Definition dialog, you can:

A. Select the module series.

B. Make sure the Major and Minor Revision numbers match your

module’s revision.

C. Choose an Electronic Keying method.

D. On the 1732E-IB8M8SOER module, select the Connection type.

Available options are Data and Listen Only.
(This field is not available for 1732E-OB8M8SR module.)

E. Select the Timestamp Format.

On the 1732E-IB8M8SOER module, the options available are
Per Point, First In First Out, and None.
On the 1732E-OB8M8SR module, the options available are Per
Point, and None.
For more information about timestamping format, see Use the
Sequence of Events Input and Scheduled Output Modules o
n

page 63

.

F. Click OK to return to theGeneral tab of the Module Properties

dialog.

G. On the General tab, you can click OK to close the Module

Properties dialog and download your configuration, or

H. Click the Connection tab to configure connection properties.

On 1732E-IB8M8SOER

On 1732E-OB8M8SR