Chapter 6 Configure the Module Using RSLogix 5000 Software

Set Up the Hardware

In this example, a ControlLogix chassis contains the Logix5565 processor in slot
1 and a 1756-EN2T bridge module in slot 3. The 1732E ArmorBlock module is
mounted remotely.

To work along with this example set up your system as shown.

• Note that in the example application, the Logix5565 controller and

1756-EN2T module (firmware version 2.3 or higher) are assumed to be in
the slots shown.

• Verify the IP addresses for your programming terminal, 1756-EN2T

module and 1732E ArmorBlock Ethernet module.

• Verify that you connected all wiring and cabling properly.
• Be sure you configured your communication driver (for example,

AB_ETH-1 or AB-ETHIP-1) in RSLinx software.

Logix5565

1756-EN2T

EtherNet/IP

Logix5565

LINK2

LINK1

NET

MOD

X10

X100

X1

AUX POWER

Local

Chassis

1732E
ArmorBlock

Logix5565
Controller (slot 1)

1756-EN2T
192.168.1.1 (slot 3)

Data

Switch

192.168.1.100

Programming
Terminal

0

1732E ArmorBlock

Ethernet Module

192.168.1.20

44971

3

2

Slot

1

Embedded
Technology