Publication 1734-UM007D-EN-P - December 2005

3-6 Communicate with Your Module

Gray to Binary Conversion

No/Yes

Convert data from Gray to
binary

SSI Word Delay Time (t

m

)

16

µs… to 64ms (64µs)

Delay time between
successive SSI data words

SSI Word Filter Control

Off, Low, Med, High, Max

Corresponds to the number
of successive equal SSI data
words that must be received
by the module in order to
update the real-time present
SSI data word.

Standardization

Off/On

Off = Use entire data word
length specified by Data
Word Length parameter.
On = Data is right-shifted
the number of bits specified
in the Trailing Bits
parameter.

Trailing Bits

0… 16

Sensor Resolution

1… 65535

Total number of
positions/revolution for a
rotary encoder,
positions/stroke for a linear
displacement transducer, or
maximum counts for
distance measurement.

Sensor Cycles

1… 65535

Total number of revolutions
for a rotary encoder, strokes
for a linear displacement
transducer

Latch Input

Off, Rising Edge, Falling
Edge, Both Edges

Master unlatches data by
transmitting the LACK bit
over the network

Comparator 1

Not Active, Up Direction,
Down Direction, Both
Directions

Module compares data to
value from the master. Only
one Compare value can be
active.

Comparator 2

Not Active, Up Direction,
Down Direction, Both
Directions

Module compares data to
value from the master. Only
one Compare value can be
active.

(1)

Default values are in bold.

Parameter

Value

(1)

Notes