A - specifications, Electrical specifications, Environmental specifications – Rockwell Automation 1747-DCM,D17476.8 Direct Communication Module User Manual

Page 65: Network specifications, Appendix a, Specifications

Advertising
background image

A

Appendix

A–1

Specifications

This appendix provides the following module and system specifications.

electrical specifications

environmental specifications

network specifications

It also discusses throughput time for the DCM.

Backplane Current Consumption

360mA at 5V

Operating Temperature

0

°

C to 60

°

C (32

°

F to 140

°

F)

Storage Temperature

40

°

C to

+

85

°

C (

40

°

F to

+

185

°

F)

Humidity Rating

5% to 95% noncondensing

Agency Certification
(when product or packaging is marked)

CSA certified

CSA Class I, Division 2
Groups A, B, C, D certified

UL listed

CE marked for all applicable directives

Baud Rate

Maximum Cable Distance

(Belden 9463)

Resistor Size

Us n

xten e

57.6K baud

10,000 feet at 57.6K baud

Using Extended

o e apab l t

115.2K baud

5,000 feet at 115.2K baud

82

W 1/2 Watt

Node Capability

230.4K baud

2,500 feet at 230.4K baud

82

W 1/2 Watt

Not Using

57.6K baud

3048 meters (10,000 feet)

1

W 1

Not Using
Extended Node

apab l t

115.2K baud

1524 meters (5,000 feet)

150

W 1/2 Watt

Extended Node
Capability

230.4K baud

762 meters (2,500 feet)

82

W 1/2 Watt

Electrical Specifications

Environmental Specifications

Network Specifications