1-2 Install InView Marquee Message Display

Change the Serial Address

A serial address for an InView sign is a number from 1 to 254 in
hexadecimal (01 to FE). All signs leave the factory with a default
address of 1 or 01.

This serial address is resident in the InView display and is used for
RS485 networking. If one of the factory network communications
modules are used (2706-Pxxxx), this serial address is typically left at
its factory default and the network node or IP address is set in the
factory network communication module.

Checkout Procedure

After you install a sign according to the Electrical and Mounting
Instructions, make sure the sign is installed properly by applying
power to it. The following information should be displayed on the
sign.

• Firmware part number and version letter (xxxx).
• Amount of RAM in the sign, (256K).
• Serial address of the sign (a number from 01 to FE or from 1 to

254).

Electrical Connections for
2706-P42, 2706-P43 and
2706-P44 Displays

To connect the 2706-P42, 2706-P43, and 2706-P44 displays:

1. Remove the power supply cover by unscrewing its 6 screws.

Save the screws for a later step.

IMPORTANT

Power wiring must be in accordance with Class I,
Class II and Class III Division 2 wiring methods
(Articles 501-4(b), 502-4(b) and 503-3(b) of the
National Electrical Code, NFPA70) and in
accordance with the local authority having
jurisdiction.

WARNING

Hazardous voltage. Contact with high voltage may
cause death or serious injury. Always disconnect
power to sign prior to servicing.