Publication 2706-UM016D-EN-P - March 2006

4-10 InView Protocol

Or

Update Variable on a Specific Display

Update variable 5 with the value of 87 on display address 006.

Update a Variable on a Specific Display

Modbus ASCII Protocol to
Download and Preview
Messages

Modbus ASCII is an industrial data communications protocol that has
been implemented in Allen-Bradley’s InView Protocol. It is a master
and slave protocol providing for one master and up to 247 slaves.
Each slave is assigned a unique address, because only the master can
initiate a transaction. The protocol controls the query and response
that takes place between master and slave devices as in Figure .

The Modbus ASCII protocol is incorporated into the InView Industrial
Protocol that allows displays to connect to a Modbus ASCII
communications network. These displays receive applicable Modbus
ASCII protocol and limited InView Sign Communication protocol
(used during the download and preview of messages). Messages are
pre-loaded into the displays, and then triggered by writing Modbus
ASCII instructions to specific registers in the display.

Master and Slave Query/Response Cycle

Name

[CTRL][V]

Variable Data

Backslash

Variable #

Backslash

Display
address

Return

ASCII

^V

2395

\

0

\

255

^M

Hex

\16

\32\33\39\35

\5C

\30

\5C

\32\35\35

\0D

Name

[CTRL][V]

Variable Data

Backslash

Variable #

Backslash

Display
address

Return

ASCII

^V

87

\

5

\

6

^M

Hex

\16

\38\37

\5C

\35

\5C

\36

\0D

Slave Address
Function Code

Data

Error Check

Slave Address
Function Code

Data

Error Check

Master

Slave