Back-to-back mount -19, Back-to-back mount – Rockwell Automation 2706-P42_P43_P44_P72_P74_P92_P94 InView Marquee Message Display User Manual User Manual

Page 27

Advertising
background image

Publication 2706-UM016D-EN-P - March 2006

Install InView Marquee Message Display 1-19

Back-to-back Mount

1. Attach the brackets to the sign in the ceiling mount position with

the hex bolts supplied.

2. Match the signs together back-to-back and connect them

together using a total of six 5/16” bolts and nuts (not supplied).

3. Attach chains (not supplied) to the top mounting holes of the

bracket to hang the signs from the ceiling.

Electrical Connections for
2706-P92C and 2706-P94C
Signs

Open the front of the sign case by turning the half-turn latches
to the left with a large screwdriver. On the 2706-P92C, there are
3 half-turn latches; on the 2706-P94C there are 5. Carefully let
the front of the case drop forward.

Second
sign

First
sign

Second
mounting
bracket

First
mounting
bracket

Attach chains here

TIP

Use chains capable of supporting 4 times the total
weight of the signs.

WARNING

HAZARDOUS VOLTAGE

• Contact with high voltage may cause death or

serious injury. Always disconnect power to sign
prior to servicing.

• Maintain Separation of circuits. Route the

incoming power directly to the power connection
terminal block.

• Do not run the power wiring over the logic board

or optional Communication board.

Advertising