Publication 2706-UM016D-EN-P - March 2006

InView System Connectivity 2-11

Display Setup

To set up your display:

1. Start the InView messaging software.

2. Create a project.

The software prompts for a project file name, a project name,
and description. Once this is done, the project name and
description appears in the Displays box.

3. The software then prompts for a display name, display

description, display type, and the number of that particular
display that is used in the system (1 to 100 of the same display
type).

4. Select one for the number of displays (once displays have been

assigned a unique address, more than one can be added at
once).

5. Select Next.

6. The software then prompts for the address of the display,

heartbeat, TCP/IP settings (if applicable), and the serial com port
settings.

Use the default settings of 9600, None, 8, and 1.

7. Select Next.

8. When the software prompts for a message file association, check

Create a New Message File.

9. Enter the message file name and select Finish.

The message editor window is displayed.

Set the IP Address

For the 2706-P22, 2706-P4x, and 2706-P7x terminals, separate
communication modules are needed to place the display on the
network. The 2706-P9x displays have Ethernet TCP/IP built in. To add
any other network protocol to the 2706-P9x, a separate
communication module is needed.

The Ethernet TCP/IP configuration utility is installed as part of the
Inview messaging software package. When first opening the InView
messaging software, you are asked to create a display and a message
file. After the display is created you can configure the IP address of
the 2706-PENET1 module.