Appendix

C

Temperature Protection in NEMA-Rated
Enclosures

Some InView signs in NEMA-rated enclosures have automatic
temperature controls that help to protect the sign from damage when
the internal temperature of the sign is too hot to continue normal
operation.

If the internal temperature of the sign reaches a pre-determined
dimming point, the LED output from the sign is forced into a 50
percent reduced power mode, effectively dimming the brightness of
LED output by about 50 percent.

If the internal temperature of the sign continues to increase, another
sensing circuit will execute an automatic shut down to protect the sign
from damage. The LED output from the sign is turned off.

The dimming and shutdown points are listed in the table below. Once
the temperature drops below the auto-shutdown threshold, the LED
output is turned on at the dimming level. Once the temperature drops
below the dimming threshold, auto-dimming is disabled and the LED
brightness is back to 100 percent.

Model

Enclosure

Dimming Point

Auto-Shutdown On

2706-P42, 2706-P44

NEMA 2

55 °C (131 °F)

70 °C (158 °F)

NEMA 12

55 °C (131 °F)

70 °C (158 °F)

2706-P43

NEMA 12

55 °C (131 °F)

70 °C (158 °F)

2706-P72, 2706-P74

NEMA 2

55 °C (131 °F)

70 °C (158 °F)

NEMA 12

55 °C (131 °F)

70 °C (158 °F)

NEMA 4, NEMA 4x

55 °C (131 °F)

70 °C (158 °F)

2706-P92, 2706-P94

NEMA

55 °C (131 °F)

75 °C (167 °F)

TIP

Take into account the effects of ambient temperature
when evaluating mounting locations for the sign.
You should always maintain recommended clearance
distances around the sign and avoid poorly
ventilated mounting locations that could be subject
to radiation, convection, conduction or other thermal
transfer effects.