Supply Voltage at the Device

24V dc ±15% (use a SELV-rated supply according to EN IEC60950)

(The external voltage supply must be capable of buffering brief mains interruptions of 20 ms, as

specified in IEC/EN 60204-1.)

Residual Ripple

± 10% maximum

Supply Current (no load)

275 mA max., exclusive of OSSD1 and OSSD2 loads (up to an additional 0.5A each)

Response Time

Dependent on number of sensing beams (see Section 2.1 for models and number of beams):

10 beams – 9 ms

60 beams – 19 ms

110 beams – 30 ms

160 beams – 40 ms

20 beams – 11 ms

70 beams – 21 ms

120 beams – 32 ms

180 beams – 43 ms

30 beams – 13 ms

80 beams – 23 ms

130 beams – 34 ms

200 beams – 48 ms

40 beams – 15 ms

90 beams – 25 ms

140 beams – 36 ms

220 beams – 52 ms

50 beams – 17 ms

100 beams – 27 ms

150 beams – 38 ms

240 beams – 56 ms

For cascaded systems, also see Section 7.4.

CSSI Response Time

(SLSC.. cascade models only)

Response time for a cascade receiver due to opening contacts at the cascade interface (CSSI): 40 ms

max (contacts must open for 60 ms minimum). See Section 7.5.

Recovery Time — Blocked to Clear

(OSSDs turn ON; varies with total

number of sensing beams and

whether Sync beam is blocked)

Beam 1 (Sync Beam)

All Other Beams

14 mm Models

109 ms to 800 ms

33 ms to 220 ms

30 mm Models

81 ms to 495 ms

25 ms to 152 ms

EDM Input

+24V dc signals from external device contacts can be monitored (one-channel, two-channel or no

monitoring) via EDM1 and EDM2 terminals in the receiver (see Section 3.5.3).

High Signal: 10 to 30V dc at 30 mA typical

Low Signal: 0 to 3V dc

Dropout Time: 200 ms max.

Reset Input

The Reset input must be high for 1/4 to 2 seconds and then low to reset the receiver.

High Signal: 10 to 30V dc at 30 mA typical

Low Signal: 0 to 3V dc

Closed Switch Time: 1/4 to 2 seconds

2.7.3 Receiver Specifications

Supply Voltage at the Device

24V dc ±15% (use a SELV-rated supply according to EN IEC60950)

(The external voltage supply must be capable of buffering brief mains interruptions of 20 ms, as

specified in IEC/EN 60204-1.)

Residual Ripple

± 10% maximum

Supply Current

100 mA max.

Remote Test Input

(Optional – available only on

model SLSE..-..Q5 emitters)

Test mode is activated either by applying a low signal (less than 3V dc) to emitter TEST #1 terminal for a

minimum of 50 milliseconds, or by opening a switch connected between

TEST #1 and TEST #2 for a minimum of 50 milliseconds. Beam scanning stops to simulate a blocked

condition. A high signal at TEST #1 deactivates Test Mode. (See Section 3.5.6 for more information.)

High Signal: 10 to 30V dc

Low Signal: 0 to 3V dc

Input Current: 35 mA inrush, 10 mA max.

Controls and Adjustments

Scan Code Selection: 2-position switch (code 1 or 2). Factory default position is code 1.

Status Indicators

One bi-color (Red/Green) Status indicator – indicates operating mode, lockout or power OFF

condition

7-Segment Diagnostic indicator (1 digit) – indicates proper operation, scan code, or error code

See Figure 1-4 for indicator locations and Section 4.4 for indicator conditions.

Wavelength of Emitter Elements

Infrared LEDs, 950 nm at peak emission (14 mm) 850 nm at peak emission (30 mm)

2.7.2 Emitter Specifications