Overview, Troubleshooting and maintenance, 1 receiver error codes (continued) – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 51

Advertising
background image

P/N 133487

49

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

Overview

49

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

EZ-SCREEN

Instruction Manual

Troubleshooting and Maintenance

5.1.1 Receiver Error Codes (continued)

Diagnostic

Display

Error Description

Cause of Error and Appropriate Action

EDM 2 Error

EDM 2 configuration not valid (wiring or

switch).

Verify that the EDM wiring is correct and that the external devices meet the

requirements described in Section 3.5.3.

If the error continues, remove power to the guarded machine, disconnect the

OSSD loads, disconnect the EDM input signals, configure EDM for No Monitoring

(per Section 3.5.3) and conduct the Initial Checkout procedure (Section 3.4).

If the error clears, the problem is in the External Device contacts or wiring, or is

a response-time problem of the external devices. Verify that the EDM wiring is

correct and that the external devices meet the requirements described in Section

3.5.3.

If the error continues, check for noise on the EDM inputs (see Section 5.3).

Fixed Blanking Error

This error occurs when beam(s) that

have been blanked (programmed to

ignore a fixed object) become clear

when the object is removed or moved.

• Reposition the object and perform a key reset (or cycle power).

• Re-program (teach) the fixed blanked object(s), see Section 3.4.3.

Programming Timeout Error

This error occurs when the Fixed

Blanking programming mode (teach)

exceeds the ten-minute limit.

• Re-program (teach) the fixed blanked object(s), see Section 3.4.3.

Cascade Configuration Error

This error occurs when the configuration

sequence is incorrectly followed,

receiver(s) 2, 3 or 4 are configured,

or receiver 1 is moved to a different

position in the cascade.

The CSSI Input channel(s) are shorted together or to another source of power or

ground.

Configure ONLY the first receiver in the cascade (connected to the machine

interface). All other receivers must be set for 2-Ch. EDM (E2) and Trip Output (T),

see Section 7.7.

Re-configure the first receiver to adapt system to changes or replacement of other

receivers, see Section 7.7.

NOTE: In a cascaded system, all receivers are connected together, and all

emitters are connected together.

Excessive Noise Error –

Reset Interface

This error can occur due to excessive

levels of electrical noise.

• Perform a reset per Section 4.3.

If the error clears, perform a Daily Checkout procedure (per Section 6.3; Daily

Checkout Card) and if OK, resume operation. If the System fails the Daily

Checkout procedure, replace the receiver.

If the error continues, check the ground connection (pin 7).

If the sensor has a good earth ground connection to pin 7, perform the Initial

Checkout procedure (Section 3.4).

If the error clears, check for sources of electrical noise (see Section 5.3).

If the error continues, replace the receiver.

Excessive Noise Error –

EDM Interface

This error can occur due to excessive

levels of electrical noise.
Excessive Noise Error –

Cascade Input

This error can occur due to excessive

levels of electrical noise.

Flashing

Cascade Input Simultaneity

Operation of channels A and B

mismatch > 3 seconds.

• Check operation of Channel A and Channel B of cascade input.

Cycle power or cycle the input. See Sections 7.8 and 7.9.