Overview, Installation and alignment, Ez-screen instruction manual – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 41

Advertising
background image

P/N 13348

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Overview

39

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN
Instruction Manual

Installation and Alignment

Figure 3-21. Generic hookup – FSDs (2-channel EDM, manual reset)

+24V dc

0V dc

Receiver

8-pin male

Euro-style

face view

Bn (Pin #1)

Gn/Ye (#7)

Bu (#6)

Bk (#5)

Wh (#4)

Vi (#8)

Or (#3)

Or/Bk (#2)

+24V dc

Ground

0V dc

OSSD1

OSSD2

Reset*

EDM1

EDM2

FSD

2

FSD

1

Single-Channel

Safety Stop

Circuit

Dual-Channel

Safety Stop

Circuit

NOTE: Do not exceed OSSD maximum load
capacitance specification.

*Trip (auto reset) – Not connected

See Table 2.2 for further

QDE-8..D cable information.

Figure 3-22. Generic hookup – self-checking Safety Module, Safety Controller, Safety PLC (no monitoring, automatic reset)

+24V dc

0V dc

Receiver

8-pin male

Euro-style

face view

Bn (Pin #1)

Gn/Ye (#7)

Bu (#6)

Bk (#5)

Wh (#4)

Vi (#8)

Or (#3)

Or/Bk (#2)

Jumper

+24V dc

Ground

0V dc

OSSD1

OSSD2

Reset*

EDM1

EDM2

*Trip (auto reset) – Not connected

See Table 2.2 for further

QDE-8..D cable information.

S1

A1 A1 A2 A2

S2

S3

SC22-3

Safety Controller

NOTE: EZ-SCREEN receiver DIP switches are configured

for “Trip” (T) output and 2-channel EDM (E2). If
the Auxiliary output is to be used, configure the
EZ-SCREEN receiver for 1-channel EDM (E1) and
connect pin #3 (Or) to +24V dc.

Advertising