Overview, Installation and alignment, Warning – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 42: Channel edm 1-channel edm, Ez-screen instruction manual, Use of transient suppressors

Advertising
background image

40

P/N 133487

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

Overview

40

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

EZ-SCREEN

Instruction Manual

Installation and Alignment

+24V dc

0V dc

S1

S2

Y4

Y2

14

24

34

S3

S4

Y3

Y1

13

23

33

K2

K1

Machine

Control

Feedback (optional)

MPCE

2

MPCE

1

Receiver

8-pin male

Euro-style

face view

IM-T-9A***

Bn (Pin #1)
Gn/Ye (#7)

Bu (#6)

Bk (#5)

Wh (#4)

Vi (#8)

Or (#3)

Or/Bk (#2)

*

*

Reset**

* Installation of transient (arc) suppressors

across the coils of MPCE1 and MPCE2 is

recommended (see Warning).
** Trip (auto reset) – Not connected
*** Other interfacing modules and solutions

available, see Section 2.3 or the

Banner Safety Catalog.

See Table 2.2 for further QDE-8D cable

information.

Fig ure 3-23. Generic hookup – Interface Module (1-Channel or 2-Channel EDM, manual reset)

+24V dc

+

0V dc

S1

S2

Y4

Y2

14

24

34

S3

S4

Y3

Y1

13

23

33

K2

K1

Machine

Control

Feedback (optional)

MPCE

2

MPCE

1

Receiver

8-pin male

Euro-style

face view

IM-T-9A***

Aux. out

Bn (Pin #1)

Gn/Ye (#7)

Bu (#6)

Bk (#5)

Wh (#4)

Vi (#8)

Or (#3)

Or/Bk (#2)

*

*

Reset**

* Installation of transient (arc) suppressors

across the coils of MPCE1 and MPCE2 is

recommended (see Warning).
** Trip (auto reset) – Not connected
*** Other interfacing modules and solutions

available, see Section 2.3 or the

Banner Safety Catalog.

See Table 2.2 for further QDE-8D cable

information.

2-Channel EDM

1-Channel EDM

WARNING . . .

Use of

Transient Suppressors

If transient suppressors are

used, they MUST be installed

across the coils of the machine

control elements. NEVER install

suppressors directly across the

contacts of the IM-T-..A Module. It

is possible for suppressors to fail as a

short circuit. If installed directly across

the contacts of the IM-T-..A Module, a

short-circuit suppressor will create an

unsafe condition.

* Installation of transient (arc) suppressors across the coils

of MPCE1 and MPCE2 is recommended (see WARNING).

** Trip (auto reset) — Not connected
*** Other interfacing modules and solutions available, see

Section 2.3 or the Banner Safety Catalog.

† See Table 2.2 for further QDE-8D cable information.

Advertising
This manual is related to the following products: