7. Cascadeable EZ-SCREEN

7.1 Overview of Cascading

EZ-SCREEN emitters and receivers are also available in

cascadeable models. These models can be used as stand-

alone light screens, or can be cascaded up to four systems; see

Figure 7-1. The cascaded sensor pairs can be any length, any

number of beams, or have different resolutions

(i.e., 14 mm and 30 mm), as long as each emitter matches

its own receiver.
NOTE: EZ-SCREEN SLS models (with Inverted Display) can

be used as the end sensor pair. EZ-SCREEN Grid/

Point systems and PICO-GUARD systems can not be

interfaced with the Cascade Input.

The control reliability, installation and alignment, electrical

interface to the guarded machine, initial checkout, periodic

checkout, troubleshooting and maintenance features of

cascadeable models are functionally identical to those of the

standard models.
Electrical connections are made through M12 (or Euro-style)

quick-disconnects. The emitter has an 8-pin connector for power

and ground. Optional 5-pin emitters with Remote Test function

are available; see note at right.
The receiver has an 8-pin connector for power, ground, reset,

EDM #1 and #2, and OSSD #1 and #2. All systems in a cascade

are activating the same set of OSSD outputs, which are the

OSSDs of the master receiver.
NOTE: In a cascaded system, all receivers are connected

together, and all emitters are connected together.

7.1.1 System Components and Specifications

A stand-alone cascadeable EZ-SCREEN system includes a

compatible emitter and receiver (equal length and resolution;

available separately or in pairs), a terminator plug for the

receiver and two single-ended (machine interface) cables.
A multiple-light screen cascaded EZ-SCREEN system includes

compatible emitter/receiver pairs (up to four), a terminator plug

for the last receiver in the cascade, two single-ended cables to

interface with the machine and provide power to the system, and

pairs of double-ended (sensor interface) cables to interconnect

the emitters and the receivers in the cascade.
The terminator plug must be used on the receiver in a stand-

alone system, and on the last receiver in a multiple-system

cascade or, a QDE2R4-8..D cable interfaced with an E-stop or

other hard contacts (see Sections 7.8 and 7.9).
Available single-ended, double-ended, and splitter cables are

listed in Section 2.3. Cable lengths are limited – for both the

power cables and the interconnect cables; see Section 7.4 for

more information.

Important Note about Remote Test in Cascaded Emitters

If a cascaded system requires the Remote Test function (see

Section 1.4.4), then all emitters in the cascade must be 5-pin

emitter models (model SLSCE..-..Q5); the interconnection

between these cascaded emitters can only be accomplished

using 5-pin DEE2R-5..D cables.

7.1.2 Receiver Display

In Run mode, the 7-segment display will show:
Clear condition

Latch Output operation “ L ”

Trip Output operation

“ – ”

Blocked condition

Number of blocked beams

CSSI Input OFF or open

| |

” Solid (not flashing)

(e.g., “upstream” receiver

is blocked or in lockout)
See Section 5.1.1 if any indication is flashing.

† U.S. Patent(s) issued or pending

Figure 7-1. Multiple cascaded light screens used to guard two

areas of one machine

Power press cross-section

Receivers only, shown

with EZA-MBK-21 “L”

mounting bracket

Advertising
This manual is related to the following products: