5. Troubleshooting and Maintenance

5.1 Troubleshooting Lockout Conditions

Evaluate status indicators per Section 4.4. See Section 5.2 for

Test mode indication.
A Lockout condition causes all of the EZ-SCREEN OSSD

outputs to turn or remain OFF, sending a stop signal to the

guarded machine. Each sensor provides diagnostic error codes

to assist in the identification of the cause(s) of lockouts (see

Sections 5.1.1 and 5.1.2 or the Diagnostic Error Code label

supplied in the documentation pack).
The System provides easy methods for determining operating

problems. A Lockout condition is indicated by the following:
Emitter

Status indicator

Flashing Red

Diagnostic Display

Error code (flashing)

Receiver

Reset indicator

OFF

Status indicator

Flashing Red

Zone Indicators

OFF

Diagnostic Display

Error code (flashing)

Recovery Procedures

To recover from a Lockout condition, all errors must be corrected

and a single sensor reset sequence must be performed as

described below.

Receiver Reset

Close the receiver Reset switch for 1/4 to 2 seconds and then

open the switch (per Section 4.3), or power the sensor down,

wait a second or two, then power it up.
NOTE: If the power down/up method is used and the

EZ-SCREEN is set for Latch Output, a manual reset,

as described in Section 4.3, is required to resume full

operation.

Emitter Reset

Power the sensor down, wait a second or two, and then power

it up.

WARNING . . .

Lockouts and Power

Failures

Power failures and Lockout conditions are indication of a problem

and must be investigated immediately by a Qualified Person.

Attempts to continue to operate machinery by bypassing

the EZ-SCREEN or other safeguards is dangerous and could

result in serious bodily injury or death.

WARNING . . .

Shut Down Machinery

Before Servicing

The machinery to which the EZ-SCREEN is connected must

not be operating at any time during major service or

maintenance. This may require lockout/tagout procedures (refer

to OSHA1910.147, ANSI Z244-1, or the appropriate standard for

controlling hazardous energy). Servicing the EZ-SCREEN while

the hazardous machinery is operational could result in serious

bodily injury or death.

Advanced Diagnostics

In addition to the standard error codes (see Sections 5.1.1 and

5.1.2), the EZ-SCREEN has the ability to display advanced

diagnostic codes for the purpose of factory troubleshooting and

repair functions. These codes are generally not intended for field

troubleshooting by the EZ-SCREEN user.
These advanced codes have three digits (alternating

“Axx”/“Bxx”, where “xx” are two alpha-numeric characters);

they are displayed by holding the Reset input high (+24V dc)

or holding the Invert Display button down for five seconds

during a lockout condition. If the advanced diagnostic codes are

inadvertently displayed, simply hold the Invert Display button

down for 5 seconds to return to the standard error code display.