1.4.6 Reduced Resolution (Floating Blanking)

Reduced Resolution increases the minimum diameter of an

object that the light screen can reliably detect anywhere within

its defined area. Reduced Resolution is generally used to allow

one or more objects (usually workpiece materials) to move

through the defined area, at any point, without tripping the

OSSD safety outputs.
Selecting two-beam Reduced Resolution will reduce the overall

minimum object sensitivity, which allows multiple objects to

move through the defined area (see Section 3.4.2). The effect

is that every two consecutive beams (except for the sync beam)

can be blocked, but not cause the OSSDs to turn OFF. This is

also called “Multiple-Point Floating Blanking.”

Figure 1-2. Reduced Resolution

Resolution directly affects the minimum allowable distance

between the defined area of a light screen and the nearest

hazard point (separation distance, see Section 3.1.1). The

green status indicator on the receiver flashes when Reduced

Resolution is enabled. The ignored object size and resultant

Reduced Resolution are listed in Section 3.4.2.

1.4.7 Status Indicators

Status indicators on both the emitter and receiver are clearly

visible on each sensor’s front panel.
• Emitter:

Bi-color red/green Status indicator – shows whether power is

applied, and whether the emitter is in RUN mode, TEST mode,

or Lockout condition.

1-Digit Diagnostic Display – indicates specific error or

configuration conditions.

• Receiver:

Bi-color red/green Zone indicators – show status of a group of

beams:

- aligned and clear (green ON), or

- blocked and/or misaligned (red ON), or

- fixed blanked area (flashing green).

Yellow Reset indicator – shows System status:

- RUN mode (ON) or

- waiting for a reset (flashing).

Bi-color red/green Status indicator – shows System status:

- Reduced Resolution enabled (flashing green),

- outputs are ON or OFF (green ON or red ON), or

- the System is in Lockout condition (flashing red).

3-Digit Diagnostic Display – indicates specific error,

configuration conditions, or total number of blocked beams.

See Sections 4.4 and 5.1 for more information about specific

indicator and Diagnostic Display code meanings.

Figure 1-3. EZ-SCREEN emitter and receiver status indicators

Beams of

Defined Area

Workpiece

Press Break

Die

Emitter

Receiver

3-digit
Diagnostic
Display

Zone Indicators

(each shows

status of approx.

1/8 of the total

beams)

1-digit
Diagnostic

Display

Status Indicator
(Red/Green)

Zone 1 Indicator
(indicates beam synchronization status)

Yellow Reset

Indicator

Status Indicator
(Red/Green)

Advertising
This manual is related to the following products: