Overview, System overview, Introduction – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 3

Advertising
background image

P/N 133487

1

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

Overview

P/N 112852

1

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

EZ-SCREEN

Instruction Manual

Overview

Electrical connections are made through M12 (or Euro-style)

quick-disconnects. Some emitter models have a 5-pin connector

for power and the Test function. Other emitters and all receivers

have an 8-pin connector for power, ground, inputs and outputs.
Functions such as Trip/Latch select, Display Invert, Cascading,

Fixed Blanking, Reduced Resolution (Floating Blanking), Scan

Code select, and External Device Monitoring are described in

Section 1.4. All models require a supply voltage of +24V dc

±15%. See Section 2.4 for interfacing solutions.
Both emitter and receiver feature 7-segment Diagnostic

Displays and individual LEDs to provide continuous indication

of the EZ-SCREEN’s operating status, configuration and error

conditions. See Section 1.4.7 for more information.
This manual contains numerous WARNING and CAUTION

statements. Warnings refer to situations that could lead to

significant or serious personal injury or death. Cautions refer to

situations that could lead to slight personal injury or potential

damage to equipment.

1. System Overview

Figure 1-1. A typical EZ-SCREEN application: weld cell

1.1

Introduction

The Banner EZ-SCREEN provides a redundant, microprocessor-

controlled, opposed-mode optoelectronic “curtain of light,” or

“safety light screen.” It typically is used for point-of-operation

safeguarding, and is suited to safeguard a variety of machinery.
EZ-SCREEN is extensively FMEA (Failure Mode and Effects

Analysis) tested to establish an extremely high degree of

confidence that when properly installed, no system component

will (even if it should fail) cause a failure to danger.
In typical operation, if any part of an operator’s body (or any

opaque object) of more than a pre-determined cross section

is detected, the OSSD solid-state safety outputs will turn off.

These safety outputs are connected to the guarded machine’s

Final Switching Devices (FSDs) that control the primary control

elements (MPCEs), which immediately stop the motion of the

guarded machine.
The OSSD (Output Signal Switching Device) safety outputs

are capable of performing a “handshake” communication with

the Muteable Safety Stop Interface (MSSI) or Universal Safety

Stop Interface (USSI) found on other Banner Engineering safety

products.
Banner EZ-SCREEN is a two-piece (“two-box”) system –

comprising an emitter and a receiver, but no external controller.

The External Device Monitoring (EDM) function ensures the

fault detection capability required by U.S. Control Reliability and

ISO13849-1 Categories 3 and 4 without a third box, a controller

or a “smart” (i.e., self-checking) safety module required of

systems without EDM.
An auxiliary (aux.) output may be used to signal the state of the

OSSDs to a process controller; see Section 1.4.3.
Emitters have a row of synchronized modulated infrared

(invisible) light-emitting diodes (LEDs) in a compact rectangular

metal housing. Receivers have a corresponding row of

synchronized photodetectors. The dimensions of the light screen

created by the emitter and receiver are called the “defined

area”; its width and height are determined by the length of the

sensor pair and the distance between them. The maximum

range is dependent on the resolution; range decreases if corner

mirrors are used. Emitter and receiver pairs with 14 mm (0.55")

resolution have a maximum range of 6 m (20'), and pairs with 30

mm (1.18") resolution have a maximum range of 18 m (60').

Advertising