GROSS COOLING CAPACITIES (cont)

558D120 (10 TON)

Air Entering

Evaporator

Air Entering Condenser (F)

75

85

95

Cfm

BF

Ewb

(F)

Capacity MBtuh

Compressor

kW

Capacity MBtuh

Compressor

kW

Capacity MBtuh

Compressor

kW

Total

Sensible

Total

Sensible

Total

Sensible

3000

0.095

72

135.8

66.8

9.76

130.0

64.3

10.41

124.1

62.2

11.13

67

124.8

82.6

9.41

119.6

80.5

10.07

113.7

78.4

10.78

62

112.0

97.4

9.10

104.0

93.8

9.74

96.7

90.0

10.40

4000

0.125

72

142.4

73.2

10.00

136.0

71.1

10.67

129.5

69.1

11.38

67

130.6

93.4

9.61

125.0

91.7

10.28

118.9

89.8

10.99

62

119.8

112.7

9.27

114.5

110.2

9.94

106.9

105.9

10.63

5000

0.150

72

146.5

79.7

10.17

140.0

77.5

10.84

132.8

74.9

11.52

67

134.2

104.4

9.75

127.9

101.8

10.41

122.0

100.1

11.14

62

123.7

123.1

9.41

118.8

118.7

10.09

114.1

114.0

10.83

558D120 (10 TON) (cont)

Air Entering

Evaporator

Air Entering Condenser (F)

105

115

Cfm

BF

Ewb

(F)

Capacity MBtuh

Compressor

kW

Capacity MBtuh

Compressor

kW

Total

Sensible

Total

Sensible

3000

0.095

72

118.1

60.4

11.93

115.0

59.4

12.26

67

104.6

74.9

11.52

98.0

72.4

11.82

62

87.9

85.2

11.10

84.2

83.4

11.40

4000

0.125

72

122.7

66.9

12.13

120.0

66.4

12.48

67

111.8

87.7

11.74

103.8

84.8

12.06

62

98.5

98.5

11.41

93.4

93.4

11.78

5000

0.150

72

126.0

73.1

12.27

122.6

72.8

12.60

67

115.1

98.3

11.89

109.8

96.6

12.20

62

108.0

108.0

11.65

102.8

102.8

12.00

558D150 (12

1

2

TON)

Air Entering

Evaporator

Air Entering Condenser (F)

75

85

95

Cfm

BF

Ewb

(F)

Capacity MBtuh

Compressor

kW

Capacity MBtuh

Compressor

kW

Capacity MBtuh

Compressor

kW

Total

Sensible

Total

Sensible

Total

Sensible

3750

0.08

72

175.6

85.7

11.16

169.3

83.9

12.15

161.9

81.4

13.12

67

162.2

107.3

10.85

155.7

104.8

11.78

148.9

102.0

12.72

62

149.2

128.0

10.57

140.6

124.0

11.42

132.0

119.8

12.28

4500

0.09

72

181.0

91.4

11.32

174.2

89.6

12.31

166.8

87.0

13.30

67

167.5

116.2

11.00

160.7

113.9

11.94

153.5

111.1

12.89

62

154.2

140.3

10.69

147.0

137.0

11.58

139.1

133.2

12.46

5000

0.10

72

182.9

94.2

11.37

176.9

92.7

12.39

169.5

90.7

13.40

67

170.2

122.2

11.07

163.0

119.7

12.01

155.7

117.3

12.97

62

156.4

146.5

10.73

149.7

143.6

11.63

142.8

140.2

12.56

6250

0.12

72

187.2

102.1

11.49

181.5

100.9

12.52

173.2

98.3

13.54

67

174.7

135.3

11.19

167.3

133.4

12.14

159.5

130.8

13.11

62

161.8

160.7

10.87

155.8

155.6

11.82

149.6

149.6

12.78

558D150 (12

1

2

TON) (cont)

Air Entering

Evaporator

Air Entering Condenser (F)

105

115

Cfm

BF

Ewb

(F)

Capacity MBtuh

Compressor

kW

Capacity MBtuh

Compressor

kW

Total

Sensible

Total

Sensible

3750

0.08

72

154.9

79.0

14.16

146.2

76.1

15.09

67

141.3

99.2

13.66

132.2

95.7

14.57

62

123.0

115.5

13.17

113.1

110.3

14.07

4500

0.09

72

158.8

84.5

14.31

150.5

81.7

15.30

67

145.4

108.2

13.82

137.0

105.2

14.76

62

130.2

128.1

13.35

122.4

122.3

14.25

5000

0.10

72

160.9

87.8

14.38

152.3

85.0

15.37

67

147.6

114.3

13.91

139.4

111.6

14.87

62

135.0

134.9

13.48

127.8

127.7

14.43

6250

0.12

72

165.3

96.6

14.58

155.2

92.9

15.49

67

151.2

127.8

14.07

142.7

125.0

15.02

62

143.2

143.1

13.77

136.0

135.8

14.73

(See Legend and Notes on page 22.)