2 advanced entry calibration – Brady 3481 User Manual

Page 75

Advertising
background image

65

5.0.2

Advanced Entry Calibration


Advanced Entry Calibration is the alternate method for special-case media
types. The procedure has two parts:

1) Using different sampling algorithms, displayed sensor readings have to be

listed for each label and TOF value.

2) From this data, the best algorithm is chosen; then those values are manually

entered for the ‘Paper’, ‘Gap’ (or ‘Mark’), and ‘Empty’ variables.

+

Advanced Entry Calibration will override all previous calibration
settings; this method should be used only when Standard Calibration
has failed.


To perform an Advanced Entry Calibration:

Step

Operator Action

Displayed Message

Comment

1

(Media should be loaded
and the appropriate
Sensor Type selected.)

Turn ‘On’ the printer.



Wait until the

printer initializes
(about six
seconds).

2

Press the

key.

Raise the printhead
assembly.


You are entering

Menu Mode.

3

Press the key to
enter the Media Settings
menu.


See Section 4.1.2

for menu layout.

4

Press the key
and scroll to ‘Sensor
Calibration’.


Press the

key to abort this

procedure.

5

Press the

key.




You are entering

the calibration
submenu.