Advanced Entry Calibration (continued)

Step

Operator Action

Displayed Message

Comment

11

Proceed according to
your media type:

Die-cut stock: strip the
media from the backing
and then reinsert it into
the sensor; adjust the
Sensor Eye Mark over
the center of the backing.

Notched stock: adjust
the Sensor Eye Mark
over the center of the
notch.

Reflective stock: Adjust
the Sensor Eye Mark
over the center of the
facedown black mark.

Press the key
to select the setting and
then record the sensor
reading in a table similar
to the one shown after
Step 12, as a TOF
Value.

Next, press the
key to increment the
Gain Number.

Repeat for each of the
Gain Numbers (00-32).



Or, for reflective media:

Where ‘yyy’ is a
numerical value
representing the
current sensor
reading: useful in
locating the best
sensor position.

þ

Note: Never

position the
sensor over a
perforation when
recording a
sensor reading.


þ

Note: Do not move the position of the Media Sensor after it has been

adjusted.