Klimaire KSIL024-H219 Service Manual User Manual

Page 49

Advertising
background image

47

Indoor fan will run at auto fan of the relevant mode.

The louver operates same as in relevant mode.

If the machine switches mode between heating and cooling, the compressor will keep stopping for 15

minutes and then choose mode according to T1-Ts.

If the setting temperature is modified, the machine will choose running function again.

8.4.5 Drying mode

8.4.5.1 Indoor fan speed is fixed at breeze and can’t be changed. The louver angle is the same as

in cooling mode.

8.4.5.2 Compressor running rules

2.0

1.5

1.0

F3

F2

F1

F1

2.5

0.5

0.0

8.4.5.3 Low indoor room temperature protection

In drying mode, if room temperature is lower than 50 ºF, the compressor will stop and not resume until

room temperature exceeds 54 ºF.

8.4.5.4 Evaporator anti-freezing protection, condenser high temperature protection and outdoor unit

frequency limit are active and the same as that in cooling mode.

8.4.5.5 The outdoor fan operates the same as in cooling mode.

8.4.6 Forced operation function

8.4.6.1 Enter forced operation function:

When the machine is off, pressing the touch button will carry the machine to forced auto mode. After

this, if pressing the button once again within 5 seconds, the machine will turn into forced cooling mode.

In forced auto, forced cooling or any other operation mode, pressing touch button will turn off the

machine.

8.4.6.2 In forced operation mode, all general protections and remote control are available.

Advertising
This manual is related to the following products: