9. Troubleshooting

9.1 Indoor Unit Error Display

Display

LED STATUS

E0

EEPROM parameter error

E1

Indoor / outdoor units communication protection

E2

Zero-crossing signal error

E3

Indoor fan speed out of control

E5

Open or short circuit of outdoor temperature sensor or outdoor unit

EEPROM parameter error

E6

Open or short circuit of room or evaporator temperature sensor

E7

Outdoor fan speed out of control

P0

IBM malfunction or IGBT over-strong current protection

P1

Over voltage or too low voltage protection

P2

Temperature protection of compressor top.

P4

Inverter compressor drive error

Note: E4 & P3: Reserved function.