ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual

43

Disable

Correlations may be disabled and excluded from the analysis. To disable a
correlation, right-click on the correlation and then select the Disable option.
The software moves disabled correlations to the end of the main display and
excludes them from the calculations. To turn off the disable function for a
particular correlation, right-click on the correlation and deselect Disable. The
software will return the correlation to the correct position on the main screen
and remove the gray color.

Main screen showing a disabled correlation in the lower right (gray)

Analysis Button

Clicking on the analysis button opens the Analysis screen displaying the
correlation function and various tools for further analysis in leak position
identification.

Notes: Do not use accelerometer and hydrophone loggers together.

dB values do not display when using a hydrophone logger.

If you set the maximum time delay to 500 ms, data between 500 and
1500 ms will not be available for viewing. However, when using
hydrophones, ADS recommends setting the value to 1500 to check for
peaks.