ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual

52

Filters tab

Analysis Options and Filter Settings (Filters tab)

Note: The default values for hydrophones are different than those
shown in the image. Therefore, when using the hydrophones, ADS
does not recommend using Auto Filter.

The Analysis Options and Filter Settings dialog allows you to select various
filters and options to manage the leak detection process. The filters are band
pass filters. You can select up to three. You also can enter filters by dragging
and dropping over the frequency display.

After selecting the required filter settings and options, click on the Apply
button to apply the settings to the correlation.

Auto Filter
Auto Filter attempts to select the optimum filter settings. This mode often can
provide very good results. However, certain situations may require manual
control of filtering. ADS does not recommend using Auto Filter with
hydrophones.

Select the Auto Filter checkbox and then click on the Apply button to apply
auto filtering to the correlation display. It may take some time to complete.
When the process is complete, the dialog box will show the filters selected
automatically by the software. When necessary, cancel auto filtering and
change the filter values manually.