Emergency service – Baumer G1-G2-G0-GE-GB-GXxxx User Manual

Page 13

Advertising
background image

Manual_CANopen_BIDE_EN.docx

13/52

Baumer IVO GmbH & Co. KG

21.11.12

Villingen-Schwenningen, Germany

4.3.5. Emergency service

Internal device error or bus problems initiate an emergency message:

COB-ID

DLC Byte0 Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

80h+Node-ID

8

Error Code

Error register

1001h

Alarms 6503h

Warning 6505h

-

00h

01h

Byte 0..1: Error Codes

Error Code (hex) Meaning

0000

Error Reset or No Error

1000

Generic Error

5530

EEPROM error (from V1.04)

6010

Software reset (Watchdog) (from V1.04)

7320

Position error (from V1.04)

7510

Internal communication error (from V1.04)

8130

Life Guard error or Heartbeat error (from V1.04)

FF00

Battery low (from V1.04)

Byte 2: Error-Register

Bit

Meaning

0

Generic Error

4

Communication error (from V1.04)

7

manufacturer specific (from V1.04)

Byte 3..4 Alarms

Bit

Meaning

Wert = 0

Wert = 1

0

Position error activ

Nein

Ja

Byte 5..6 Warning

Bit

Meaning

Wert = 0

Wert = 1

2

CPU watchdog status

OK

Reset done

4

Battery charge

OK

Battery low

Byte 7: not used


Advertising