Operation – Baumer G1-G2-G0-GE-GB-GXxxx User Manual

Page 44

Advertising
background image

Manual_CANopen_BIDE_EN.docx

44/52

Baumer IVO GmbH & Co. KG

21.11.12

Villingen-Schwenningen, Germany

Changing singleturn resolution
In object 6001h, the singleturn resolution can be configured. For example 4096 (12bit) steps per revolution
(1024 = 400h):

COB ID

DLC Command

Object L

Object H Subindex Data 0

Data
1

Data
2

Data
3

600h+node ID

8

23h

01h

60h

0h

00

04

00

00


Confirmation:

COB ID

DLC Command

Object L

Object H Subindex Data 0

Data
1

Data
2

Data
3

580h+node ID

8

60h

01h

60h

0h

0

0

0

0

Changing the overall resolution
In object 6002h, the overall resolution can be set. The overall resolution and the singleturn resolution result in
the number of revolutions. Example: The singleturn resolution is set at 12 bit (4096 steps) and the overall
resolution at 24 bit (16777216) resulting in 4096 (12bit) revolutions of 4096 (12bit) steps each.

Setting the overall resolution to 4194304 (4194304 = 400000h)

COB ID

DLC Command

Object L

Object H Subindex Data 0

Data
1

Data
2

Data
3

600h+node ID

8

23h

02h

60h

0h

00

00

40

00


Confirmation:

COB ID

DLC Command

Object L

Object H Subindex Data 0

Data
1

Data
2

Data
3

580h+node ID

8

60h

02h

60h

0h

0

0

0

0

Saving the setting in the EEPROM
Object 1010h initiates the save routine for the objects below in the non-volatile memory (EEPROM). In order
to prevent unintentional saving, the message "Save" must be written in Subindex 1.

COB ID

DLC Command

Object L

Object H Subindex Data 0

Data
1

Data
2

Data
3

600h+node ID

8

23h

10h

10h

01h

73 's’

61 'a’ 76 'v’ 65 'e’


Conformation:

COB ID

DLC Command

Object L

Object H Subindex Data 0

Data
1

Data
2

Data
3

580h+node ID

8

60h

10h

10h

01h

0

0

0

0


6.3. Operation

NMT statuses
Once the encoder has been initialized, it is then in the Pre-operational mode. In this mode, SDO can be
read and written.

In order to start PDO communication, you must transmit an NMT start. The encoder is then in the
Operational mode. Any required PDOs are then transmitted. SDOs can also be read and written.

If the encoder is stopped with an NMT stop, the encoder is then in the stopped mode. In this mode, only
NMT communication is the possible, i.e. also heartbeat.