Layer setting services – Baumer G1-G2-G0-GE-GB-GXxxx User Manual

Page 18

Advertising
background image

Manual_CANopen_BIDE_EN.docx

18/52

Baumer IVO GmbH & Co. KG

21.11.12

Villingen-Schwenningen, Germany

4.3.7. Layer Setting Services

In the spring of 2000, CiA drafted a new protocol intended to ensure standardized occurrence. The procedure
is described under
Layer Setting Services and Protocol, CiA Draft Standard Proposal 305 (LSS).
The encoder is supplied by us as standard with the node ID 1 and a baud rate of 50 kBaud. Several encoders
can be connected to the bus system with the same node ID. To allow individual encoders to be addressed,
LSS is used.
Each encoder is fitted with its own unique serial number and is addressed using this number. In other words,
an optional number of encoders with the same node ID can be connected to one bus system, and then
initialized via LSS. Both the node ID and also the baud rate can be reset. LSS can only be executed in the
Stopped Mode.

Message structure

COB ID:
Master  Slave

: 2021 = 7E5h

Master  Slave

: 2020 = 7E4h

After the COB ID, an LSS command specifier is transmitted.
This is followed by up to seven attached data bytes.

COB ID cs

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7


Switch Mode Global

7E5h  04h

Mode

Reserved


Mode : 0  Operation mode

1  Configuration mode



Selective switch mode
The following procedure can be used to address a certain encoder in the bus system.

7E5h  40h

Vendor ID

reserved

7E5h  41h

Product code

reserved

7E5h  42h

Revision number

reserved

7E5h  43h

Serial number

reserved

7E4h  44h

Mode

reserved


Vendor Id

: ECh

Product code

: Internal product code for the respective encoder

Revision number : Current revision number of the encoder
Serial number

: Unique, consecutive serial number

Mode

: The encoder's response is the new mode (0=operating mode; 1=configuration mode)



Setting the node ID

7E5h  11h

Node ID reserved

7E4h  11h

ErrCode

Spec error

reserved


Node ID

: The encoder's new node ID

Error code

: 0=OK; 1=Node ID outside range; 2..254=reserved; 255Specific error

Specific error

: If Error code=255  application-specific error code.