Baumer G1-G2-G0-GE-GB-GXxxx User Manual

Page 26

Advertising
background image

Manual_CANopen_BIDE_EN.docx

26/52

Baumer IVO GmbH & Co. KG

21.11.12

Villingen-Schwenningen, Germany

Object 1005

COB ID SYNC message

Subindex

0

Data type

Unsigned 32

Access

Read write

Default

80h

EEPROM

Yes

Description

Defined COB ID of the synchronization object (SYNC)

Values

Bit 31

not defined

Bit 30

1=Sensor generates SYNC messages, 0=generates no

SYNC

message
Bit 29

1=29 bit SYNC COB ID (CAN 2.0B), 0=28 bit SYNC COB ID

(CAN 2.0A)

Bit 28..11 Bit 28..11 of the 29 bit SYNC COB ID
Bit 10..0

Bit 10..0 of the SYNC COB ID

Object 1008

Manufacturer Device Name

Subindex

0

Data type

Unsigned 32

Access

Read only

Default

It depends on the basic encoder

EEPROM

No

Description

Device name in ASCII

Values

Data 0..3:
"GXMM" = 47h 58h 4Dh 4Dh

 multivo Multiturn

"GXAM" = 47h 58h 41h 4Dh

 multivo Singleturn

"GCMM" = 47h 43h 4Dh 4Dh

 magtivo Multiturn

"GCAM" = 47h 43h 41h 4Dh

 magtivo Singleturn

"GDMM" = 47h 44h 4Dh 4Dh

 activo Multiturn

"GDAM" = 47h 44h 41h 4Dh

 activo Singleturn

"GBMM" = 47h 42h 4Dh 4Dh

 multivoPlus Multiturn

"GBAM" = 47h 42h 41h 4Dh

 multivoPlus Singleturn

Object 1009

Manufacturer hardware version

Subindex

0

Data type

Unsigned 32

Access

Read only

Default

"1.00"

EEPROM

No

Description

Hardware version in ASCII

Values

Data 0..3 31h 2Eh 30h 30h

= "1.00“

Object 100A

Manufacturer software version

Subindex

0

Data type

Unsigned 32

Access

Read only

Default

"1.00"

EEPROM

No

Description

Software version in ASCII

Values

Data 0..3 31h 2Eh 30h 30h

= "1.00“