Baumer G1-G2-G0-GE-GB-GXxxx User Manual

Page 29

Advertising
background image

Manual_CANopen_BIDE_EN.docx

29/52

Baumer IVO GmbH & Co. KG

21.11.12

Villingen-Schwenningen, Germany

6002h

0h

Total measuring range in increments

20000000h  multivo multiturn
2000h  multivo singleturn
4000000h  magtivo multiturn
1000h  magtivo singleturn
80000000h  activo/multivoPlus

multiturn

40000h  activo/multivoPlus singleturn

6003h

0h

Preset value in increments

0h

6200h

0h

Cyclical timer for PDO1

203h (see Object 1800-5)

6509h

0h

Offset

0h

650Bh

0h

Serial number

xyz (see Object 1018-4)

Object 1011

Restore parameters

The values in the RAM are overwritten by the default values (see object 1010h) by the object 1011h. In
addition, the content of the EEPROM is marked as invalid. This means that until the next data save
routine in the EEPROM, the default values are loaded in each case.
In order to prevent unintentional overwriting, the message "load" must be written in subindex 1.

COB ID

DLC Command

Object L

Object H

Subindex

Data 0

Data 1 Data 2 Data 3

600h+node ID

8

23h

11h

10h

01

6Ch 'l'

6Fh 'o' 61h 'a' 64h 'd'

Object 1014

COB ID emergency message

Subindex

0

Data type

Unsigned 32

Access

Read write

Default

80h+node ID

EEPROM

Yes

Description

Defines COB ID of the emergency object

Values

80h + Node ID

Object 1016

Consumer heartbeat time

Subindex

0

Data type

Unsigned 8

Access

Read only

Default

1

EEPROM

No

Description

Biggest supported subindex

Values

1 = Biggest supported subindex

Subindex

1

Data type

Unsigned 32

Access

Read write

Default

10000h

EEPROM

Yes

Description

Consumer heartbeat time

Values

Bit 0..15 Consumer heartbeat time in ms
Bit 16..23 Node ID

Object 1017

Producer heartbeat time

Subindex

0

Data type

Unsigned 16

Access

Read write

Default

0h

EEPROM

Yes

Description

Defines repeat time of the heartbeat watchdog service

Values

0 = Disabled, 1..65535 = Repeat time in ms