Baumer G1-G2-G0-GE-GB-GXxxx User Manual

Page 35

Advertising
background image

Manual_CANopen_BIDE_EN.docx

35/52

Baumer IVO GmbH & Co. KG

21.11.12

Villingen-Schwenningen, Germany

Object 2800

PDO1 addition (event trigger)

Subindex

0

Data type

Unsigned 8

Access

Read write

Default

0h

EEPROM

Yes

Description

The event trigger value determines how often the same PDO value is
transmitted

Values

0 =

PDO counter is switched off  Continuous transmission (time
basis from the event timer)

1..n..255 = The same PDO value is transmitted n times (time basis from event

timer)

Object 2801

PDO2 addition (event trigger)

Subindex

0

Data type

Unsigned 8

Access

Read write

Default

0h

EEPROM

Yes

Description

The event trigger value determines how often the same PDO value is
transmitted

Values

0 =

PDO counter is switched off  continuous transmission (time
basis from the event timer)

1..n..255 = The same PDO value is transmitted n times (time basis from event

timer)

Object 6000

Operating parameter

Subindex

0

Data type

Unsigned 16

Access

Read write

Default

4

EEPROM

Yes

Description

Operating parameter

Values

Bit 0 sense of rotation = 0
 clockwise; 1  counterclockwise
Bit 2 scaling function = 0
 max. resolution; 1  saved resolution

Object 6001

Resolution

Subindex

0

Data type

Unsigned 32

Access

Read write

Default

2000h = 8192 = 13Bit

 multivo

1000h = 4096 = 12Bit

 magtivo

40000h = 262144 = 18Bit

 activo/multivoPlus

EEPROM

Yes

Description

No. of steps per revolution freely selectable.
! Offset value is reset when changing the resolution!

Values

1..n.. Max. no. of steps per revolution (see object 6501)
1..n..8192

 multivo

1..n..4096

 magtivo

1..n..262144

 activo/multivoPlus

Advertising