Accessories, Choosing a location, Scsi bus requirements – Dell PowerVault 124T User Manual

Page 4

Advertising
background image

Installing the Autoloader: Dell PowerVault 124T DLT VS160 Autoloader User's Guide

file:///T|/htdocs/stor-sys/124T/en/124tvs16/install.html[12/5/2012 10:25:55 AM]

SCSI Bus Requirements

You must connect the Dell PowerVault 124T DLT VS160 autoloader to one of the following SCSI bus types:

Ultra 160 SCSI, Low-voltage Differential (LVD)

Ultra 320 SCSI, Low-voltage Differential (LVD)

Single-ended (SE) SCSI bus

NOTE: The Dell PowerVault 124T DLT VS160 autoloader is not compatible with a High-voltage Differential (HVD) SCSI

bus.

Your SCSI host adapter card must also support the SCSI bus type used to connect the autoloader. If you use a LVD SCSI bus,

use a host adapter card with a connection for a high-density (HD) 68-pin cable.

NOTE: If you use an SE SCSI bus, the tape drive's performance is limited to the maximum data transfer speed of the

bus.

NOTE: The maximum number of autoloaders supported per SCSI bus is two.

NOTE: The autoloader may not work with multiple SCSI LUNS when attached to a redundant array of independent disks

(RAID) controller. The autoloader is not recommended for use with a RAID controller. If this problem occurs, it is

recommended that the autoloader be attached to a separate SCSI bus controller on the server.

Accessories

The following accessories are shipped with the Dell PowerVault 124T DLT VS160 autoloader:

Getting Started Guide

SCSI host cable

SCSI terminator

Hardware to rack mount the autoloader (autoloader rails are included, rack rails are optional)

One magazine blank

Power cable

Documentation CD containing all of the documentation in Adobe® Portable Document Format (PDF) and supplied device

drivers

Bar code labels

TORX L-key drivers (T8 and T10)

Emergency Magazine Removal Tool

Choosing a Location

Choose a location that meets the following criteria (see "

Technical Specifications

"):

NOTICE: Do not place the autoloader on its side or upside down. Do not stack anything on top of the autoloader.

Rack

Requirements

Standard 19-inch rack with 2U (3.5 in.) of clearance.

Room

Temperature

10–35°C (50–95°F)

Power Source AC power voltage: 100–127 VAC; 200–240 VAC

Line frequency: 50–60 Hz

NOTE: Locate the AC outlet near the autoloader. The AC power cable is the product's main AC

disconnect device and must be easily accessible at all times.