Troubleshooting, Before contacting customer support – Dell PowerVault 124T User Manual

Page 46

Advertising
background image

Troubleshooting: Dell PowerVault 124T DLT VS160 Autoloader User's Guide

file:///T|/htdocs/stor-sys/124T/en/124tvs16/trouble.htm[12/5/2012 10:26:08 AM]

Back to Contents Page

Troubleshooting: Dell™ PowerVault™ 124T DLT VS160

Autoloader User's Guide

Before Contacting Customer Support

Operator Control Panel Error Display

Checking For Errors

Autoloader Logs

TapeAlert Logs

Returning the Autoloader for Service

Before Contacting Customer Support

Errors that you may experience with your autoloader can range from simple connection problems to more complex hardware

failure. Before you return your autoloader, you may be able to fix the problem yourself by following some basic

troubleshooting procedures.

Other than drive cleaning, there is no recommended routine maintenance of the Dell PowerVault 124T autoloader.

The operator control panel located at the front of the autoloader provides some troubleshooting capabilities, but is limited.

The Remote Management Unit provides more detailed information about the present state of the autoloader and past

performance, and is more helpful for troubleshooting errors.

NOTICE: If you find that you must power cycle the autoloader, do not turn the power back on for at least 10 seconds

after powering down. This allows time for the power supply to completely discharge and ensure a complete system

reset. If time is not allowed for the discharge, the system may fail to boot properly and will display a blank LCD screen.

Power cycle again, waiting at least 10 seconds, to clear the problem.

The following table describes the probable cause and suggested action for problems that you may encounter.

Table 1: Basic Troubleshooting

Problem

Probable Cause

Suggested Action

The front panel does not

display information.

The connection to the LCD

has failed.

Use the

Remote Management Unit

to troubleshoot error.

Error messages appear

on the front panel LCD

display.

An error has occurred.

Refer to

Front Panel Error Display

.

The autoloader is

operating slowly.

The autoloader, system

hardware, or host backup

software is incorrectly

configured.

Go to

support.dell.com

for configuration requirements.