Troubleshooting: Dell PowerVault 124T DLT VS160 Autoloader User's Guide

file:///T|/htdocs/stor-sys/124T/en/124tvs16/trouble.htm[12/5/2012 10:26:08 AM]

If problems recur with the original cartridge or label, replace.

If all previous steps fail, contact

support.dell.com

.

F6

Barcode No Read

Barcode label not present.

Apply valid barcode label to cartridge, or disable the barcode reader

through the Operator Control Panel or Remote Management Unit.

F7

Barcode Mismatch Error

Power cycle the autoloader.

Run the Random Moves test from either the Remote Management Unit

(RMU) or the Operator Control Panel (OCP).

Note: The Random Moves test requires a minimum of two cartridges

present within the autoloader.

If all previous steps fail, contact

support.dell.com

.

F8

Barcode Duplicate Label

Error

Duplicate barcode.

Diagnostic Error Types

F9

Diagnostic Test Failure

Power cycle the autoloader.

Re-run the failing diagnostic test.

If all previous steps fail, contact

support.dell.com

.

FA

Diagnostic Error, Drive

Reporting Write Protect

Verify that valid, not data protected media is present for test.

Run the Random Moves test from either the Remote Management Unit

(RMU) or the Operator Control Panel (OCP).

Note: The Random Moves test requires a minimum of two cartridges

present within the autoloader.

If all previous steps fail, contact

support.dell.com

.

FB

Diagnostic Error, Cleaning

Tape Inserted

FC

Diagnostic Load Tape

Prompt

This is a prompt to manually load a cartridge as required for test.

FD

Diagnostic Unknown Tape

Format

Verify that valid, not data protected media is present for test.

Run the Random Moves test from either the Remote Management Unit

(RMU) or the Operator Control Panel (OCP).

Note: The Random Moves test requires a minimum of two cartridges

present within the autoloader.

If all previous steps fail, contact

support.dell.com

.

FE

Diagnostic Invalid

Configuration

This is an indication that a minimum of two pieces of media are required for test.

Insure at least two cartridges are present in the autoloader and re-run the

failed test.