Hbx mode – Outback Power Systems MATE2 User Manual

Page 60

Advertising
background image

0

ADV------------------------------------

choose device:

FX CC DC MATE

ADV/MATE/PG1-----------------------

choose category:

HBX GRIDUSE AGS PG2

In the ADV menu, push the <MATE> soft key to

view the Advanced MATE functions.

From the ADV/MATE screen, a Control Mode

is chosen. Press the <HBX> soft key to view the

HBX screens.

What it does: HBX Mode allows control over the use of grid-supplied power based on user-

determined battery voltage and time set points. A user can maximize renewable energy use and

minimize the use of grid-supplied power through careful HBX usage.

The OutBack default values* for HBX (24V system) are the following:

• High voltage—26 volts

• Low voltage—24 volts

• Time for both high and low settings—one hour

When the battery voltage remains at 26 volts for one hour, the FX will disconnect from the

grid and the system will run on battery-supplied power. If the battery voltage falls to 24 volts

for one hour, the FX connects to the grid. During this connected period, the grid-supplied AC

current will power the loads and recharge the batteries unless the user manually shuts off the

FX charging function off. With the charger off, the grid will only power the loads, allowing

renewable energy sources to recharge the batteries. This avoids running the loads from the

batteries and repeatedly charging and discharging them using more expensive utility power.

To shut the charger function off:

• Press the <AC IN> hot key three times until the CHARGER CONTROL screen appears.

• Press the <OFF> soft key.

* Double these values for a 48V system; divide them by one half for a 12V system. These

values are not temperature compensated.