31

E1714

Unknown

error. Review

& clear SEL.

The system BIOS
determined there has been
an error in the system, but is
unable to determine its
origin.

Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.

If the problem persists,
see "Getting Help" on
page 195.

E1715

Fatal I/O

Error. Review

& clear SEL.

The system BIOS
determined there has been a
fatal error in the system.

Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.

If the problem persists,
see "Getting Help" on
page 195.

E1716

Chipset IERR

Bus ## Dev ##

Function ##.

Review &

clear SEL.

The system BIOS reported a
chipset internal error that
resides in bus ##, device
##, function ##.

Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.

If the problem persists,
see "Getting Help" on
page 195.

E1717

CPU #

internal

error. Review

& clear SEL.

The system BIOS
determined that the
specified processor has had
an internal error.

Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.

If the problem persists,
see "Getting Help" on
page 195.

Code

Text

Causes

Corrective Actions

book.book Page 31 Thursday, February 18, 2010 2:06 PM