Dell PowerEdge R810 User Manual

Page 38

Advertising
background image

38

About Your System

E2112

Memory spared

on Card x

DIMM ##.

Power cycle

AC

The system BIOS spared the
memory because it
determined that the
memory has too many
errors.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Troubleshooting
System Memory" on
page 169.

E2113

Mem mirror

OFF on DIMM

## & ##.

Power cycle

AC.

The system BIOS disabled
memory mirroring because
it has determined one half
of the mirror has had too
many errors. "## & ##"
represents the memory
module pair implicated by
the BIOS.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Troubleshooting
System Memory" on
page 169.

I1910

Intrusion

detected.

Check chassis

cover.

System cover removed.

Information only.

I1911

LCD Log Full.

Check SEL to

review all

Errors.

LCD overflow message. A
maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.

Check the SEL for details
on the events.

Remove AC power to the
system for 10 seconds or
clear the SEL.

I1912

SEL full.

Review &

clear log.

The SEL is full of events
and is unable to log any
more.

Check the SEL for more
information and then
clear the SEL.

W1228

RAID

Controller

battery

capacity <

24hr.

Warns predictively that the
RAID battery has less than
24 hours of charge left.

Allow RAID battery to
charge to greater than 24
hours of sustained charge.

If problem persists,
replace the RAID battery.
See "Installing the RAID
Battery" on page 130.

Code

Text

Causes

Corrective Actions

book.book Page 38 Thursday, February 18, 2010 2:06 PM

Advertising